B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 311 -
4.35 PARAMETERS OF DISPLAYING OPERATION TIME AND
NUMBER OF PARTS
#7 #6 #5 #4 #3 #2 #1 #0
6700 PRT PCM
[Data type] Bit
PCM M code that counts the total number of machined parts and the number
of machined parts
0 : M02, or M30, or an M code specified by parameter No.6710
1 : Only M code specified by parameter No.6710
PRT Upon reset, signal PRTSF <F062#7>, which indicates that a required
number of parts has been reached, is:
0 : Turned off.
1 : Not turned off.
6710
M code that counts the total number of machined parts and the number of
machined parts
[Data type] 2-word
[Valid data range] 0 to 255 except 98 and 99
The total number of machined parts and the number of machined
parts are counted (+1) when the M code set is executed.
NOTE
Set value 0 is invalid (the number of parts is not
counted for M00). Data 98 and 99 cannot be set.
6711 Number of machined parts
The following parameter can be set at "Setting screen".
[Data type] 2-word
[Unit of data] One piece
[Valid data range] 0 to 99999999
The number of machined parts is counted (+1) together with the total
number of machined parts when the M02, M30, or a M code specified
by parameter No.6710 is executed.
NOTE
The number of parts is not counted for M02, M03,
when bit 0 (PCM) of parameter No. 6700 is set to
1.