B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 25 -
4.4 PARAMETERS OF REMOTE DIAGNOSIS
#7 #6 #5 #4 #3 #2 #1 #0
0002 RDG
[Data type] Bit
RDG Remote diagnosis is:
0: Not performed.
1: Performed.
If an RS-232-C serial port is used to carry out remote diagnosis,
connect and set up the modem, cable, and the like, then set 1 in this
parameter.
#7 #6 #5 #4 #3 #2 #1 #0
0201 NCR ASC SB2
[Data type] Bit
SB2 The number of stop bits is
0: 1.
1: 2.
To carry out remote diagnosis, set 0.
ASC The code to be used for data output is:
0: ISO code.
1: ASCII code.
To carry out remote diagnosis, set 1.
NCR EOB (end of block) is output as:
0: "LF""CR""CR".
1: Just as "LF".
To carry out remote diagnosis, set 1.
0203 Baud rate (for remote diagnosis)
[Data type] Byte
Set the baud rate of data input/output by remote diagnosis, with
reference to the tables given below.
When using an RS-232-C serial port
Set value Baud rate (bps) Set value Baud rate (bps)
1 50 7 600
2 100 8 1200
3 110 9 2400
4 150 10 4800
5 200 11 9600
6 300
12 19200
NOTE
The tables above indicate the baud rates of
communication between the CNC and modem. The
actual communication baud rate may be lowered,
depending on the modem and communication line.