4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 32 -
4.9 PARAMETERS OF AXIS CONTROL/INCREMENT SYSTEM
#7 #6 #5 #4 #3 #2 #1 #0
1001 INM
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Bit
INM Least command increment on the linear axis
0 : In mm (metric system machine)
1 : In inches (inch system machine)
#7 #6 #5 #4 #3 #2 #1 #0
IDG XIK SFD DLZ JAX
1002
IDG XIK AZR SFD DLZ JAX
[Data type] Bit
JAX Number of axes controlled simultaneously in manual continuous feed,
manual rapid traverse and manual reference position return
0 : 1 axis
1 : 3 axes
DLZ Function setting the reference position without dog
0 : Disabled
1 : Enabled (enabled for all axes)
NOTE
1 This function can be specified for each axis by
DLZx, bit 1 of parameter No.1005.
2 For a system including an axis of Cs contour
control or spindle positioning, avoid using this
parameter. Use bit 1 (DLZx) of parameter No.
1005 instead to set just a required axis.
SFD The function for shifting the reference position is
0: Not used.
1: Used.
AZR When no reference position is set, the G28 command causes:
0: Reference position return using deceleration dogs (as during
manual reference position return) to be executed.