B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 37 -
#7 #6 #5 #4 #3 #2 #1 #0
OKIx ALZx RTLx
1007
OKIx
[Data type] Bit axis
RTLx The reference position return operation for a rotation axis is:
0 : Of rotation axis type.
1 : Of linear axis type.
NOTE
The rotation axis type reference position return
operation and the linear axis type reference
position return operation differ in behavior as
follows, depending on when the dog (the
deceleration signal for reference position return) is
pressed:
• Linear axis type:
When the dog is pressed before the one-rotation
signal is seized, P/S alarm No. 090 is issued.
• Rotation axis type:
When the dog is pressed before the one-rotation
signal is seized, the reference position return
operation is continued without issuing an alarm.
ALZx An automatic reference position return operation causes:
0 : A return to the reference position by positioning.
When a reference position return has not been performed even
once since power-on, a return to the reference position is
performed in the same sequence as for the manual reference
position return operation.
1 : A return to the reference position in the same sequence as for the
manual reference position return operation.
NOTE
This parameter has no influence on axes for which
a reference position return is performed without
dogs.
OKIx In reference position setting by pressing an axis against a stopper,
after a reference position return is completed, P/S alarm 000 is:
0 : Issued.
(If this setting is made, an absolute position detector is required
when the function of reference position setting by pressing an
axis against a stopper is used.)
1 : Not issued.
(If this setting is made, no absolute position detector is required
even when the function of reference position setting by pressing
an axis against a stopper is used.)