4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 62 -
NOTE
This parameter selects a feedrate for reference
position return performed without dogs. This
parameter also selects a feedrate when manual
reference position return is performed according to
bit 7 (SJZ) of parameter No.0002 using rapid
traverse without deceleration dogs after a
reference position is set.
<For T series>
F8A Valid data range for an F command in feed-per-minute mode
0: Range specified with bit 0 (MIF) of parameter No.1403
1:
Increment system Units IS-A, IS-B IS-C
Millimeter input mm/min 0.001 to 240000. 0.001 to 100000.
Inch input inch/min 0.00001 to 9600. 0.00001 to 4000.
Rotation axis deg/min 1 to 240000. 1 to 100000.
<For M series>
F8A Valid data range for an F command with a decimal point in feed-per
minute mode
0:
Increment system Units IS-A, IS-B IS-C
Millimeter input mm/min 0.001 to 99999.999.
Inch input inch/min 0.00001 to 999.99999.
Rotation axis (mm) deg/min 1 to 240000. 1 to 100000.
Rotation axis (inch) deg/min 1 to 9600. 1 to 4000.
1:
Increment system Units IS-A, IS-B IS-C
Millimeter input mm/min 0.001 to 240000. 0.001 to 100000.
Inch input inch/min 0.00001 to 9600. 0.00001 to 4000.
Rotation axis deg/min 1 to 240000. 1 to 100000.
FRV For inch input, the valid range of the feedrate specified for feed per
revolution is:
0 : Standard range. (F0.000001 to 9.999999 inches per revolution)
1 : Extended to F50.0 inches per revolution. (F0.000001 to
50.000000 inches per revolution)
HCF In AI contour control (M series), as the feedrate of helical
interpolation:
0 : A composite feedrate is specified.
1 : A feedrate along the arc is specified.
FC0 Specifies the behavior of the machine tool when a block (G01, G02,
G03, etc.) containing a feedrate command (F command) that is 0 is
issued during automatic operation, as follows:
0: A P/S alarm (No.011) is displayed, and the block is not executed.
1: No alarm is displayed, and the block is executed.
#7 #6 #5 #4 #3 #2 #1 #0
1405 FCI EDR