1. DISPLAY AND OPERATION
B–64115EN/01
90
(1)Display start condition
100 : Draws a waveform for the stored data.
(2)Sampling period: Invalid
(3)Trigger: Invalid
(4)Data number: The table below lists the numbers of the data items for
which a waveform can be displayed (n = 1 to 4). Numbers for which
no data is stored cannot be specified.
Data No. Description Units
00 Does not display a waveform. –
0n Servo error (8 ms) for the n–th axis (positional devi-
ation)
Pulses
(detection units)
1n Pulse distribution for the n–th axis (move command) Pulses
(input increments)
2n Torque for the n–th axis (actual current) % (relative to maxi-
mum current)
5n Actual speed for the n–th axis min
–1
6n Command current for the n–th axis % (relative to maxi-
mum current)
7n Thermal simulation data for the n–th axis
(when the parameter No.3121 is set to 0.)
% (OVC alarm ratio)
111 Load meter for the n–th spindle
(when the parameter No.3121 is set to 1.)
% (relative to maxi-
mum output)
(5)Data units: Weight of data when 1 is specified. The data units are
automatically specified for each data item and need not be set unless
the units must be changed for some reason.
[Valid data range] 1 to 1000
[Unit] 0.001
(6)Signal address: Invalid
D Waveform diagnosis
parameters (storage
type)