B–64115EN/01
4. INTERFACE BETWEEN CNC AND PMC
277
The specified trigger conditions are displayed at the top of the screen.
TRIGER *MODE : ON G008. 7 : 2 : 003 NET 0001-00005
Specified conditions are displayed.
To turn off the monitor display at the signal’s falling edge (as the signal
changes from 1 to 0), enter the desired data and press the required keys
in the order shown below.
Signal name/address EOB Trigger checkpoint EOB
Count [TRGOFF]
4 Press the [START] soft key to activate the trigger function.
³ While the trigger function is operating,
TRG
is displayed at the
lower right corner of the screen. When the trigger conditions
are satisfied,
TRG
disappears and the monitor screen is locked.
5 To interrupt the trigger function, press the [STOP] soft key while
the function is effective.
³ In this case, the specified trigger conditions remain effective.
Pressing the [START] soft key reinstates the trigger function.
6 To search for the instruction where the program was stopped by the
trigger function and blink that instruction, press the [TRGSRC]
soft key.
NOTE
1 Because parameters are stored in the nonvolatile memory,
they are not lost even if the power is turned off.
2 When bit 2 of keep relay K18 is set to 1 after parameters for
sampling are specified, the trigger function automatically
starts when the power is turned on.
(5)Displaying a divided ladder program (WINDOW)
A ladder program can be divided into up to six sections, and the
individual sections displayed on the screen simultaneously.
1 Press the [WINDOW] soft key.
SEARCH ADRESS TRIGER WINDOW
DIVIDE CANCEL DELETE SELECT WIDTH
RET
2 Press the [DIVIDE] soft key to divide the dynamic display screen
into the desired number of sections.
: Each time the key is pressed, the screen is divided.