4. INTERFACE BETWEEN CNC AND PMC
B–64115EN/01
310
f) STOP CONDITION/TRIGGER/ADDRESS
This item becomes settable when “TRIGGER” is set as the trace
stop condition. Set a trigger address for stopping trace
operation.
g) STOP CONDITION/TRIGGER/MODE
This item becomes settable when “TRIGGER” is set as the trace
stop condition. Set a trigger mode for stopping trace operation.
D RISING EDGE : Stops trace operation automatically
on the rising edge of the trigger signal.
D FALLING EDGE : Stops trace operation automatically
on the falling edge of the trigger signal.
D BOTH EDGE : Stops trace operation
automaticallyon a transition of the
trigger signal.
h) STOP CONDITION/TRIGGER/POSITION
This item becomes settable when “TRIGGER” is set as the trace
stop condition. By using a ratio to the sampling time (or count),
set where to place a stop trigger occurrence position in the entire
sampling time (or count).
i) SAMPLING CONDITION
This item becomes settable when “SIGNAL TRANSITION” is
set as the sampling mode. Set a sampling condition.
D TRIGGER : Performs sampling when the
sampling trigger condition is
satisfied.
D ANY CHANGE : Perform sampling when a sampling
address signal transition occurs.
j) SAMPLING CONDITION/TRIGGER/ADDRESS
This item becomes settable when “SIGNAL TRANSITION” is
set as the sampling mode and “Trigger” is set as the sampling
condition. Set an address used to trigger sampling.
k) SAMPLING CONDITION/TRIGGER/MODE
This item becomes settable when “SIGNAL TRANSITION” is
set as the sampling mode and “Trigger” is set as the sampling
condition. Set a trigger condition mode.
D RISING EDGE : Performs sampling on the rising edge
of the trigger signal.
D FALLING EDGE : Performs sampling on the falling
edge of the trigger signal.
D BOTH EDGE : Performs sampling on a signal
transition.
D ON : Performs sampling when the trigger
signal is on.
D OFF : Performs sampling when the trigger
signal is off.