8. TROUBLESHOOTING
B–64115EN/01
480
If the FSSB does not become ready to open in 4, alarm 5134 is issued.
If an error is detected in 5, alarm 5137 is issued.
If the FSSB does not open within a fixed period of time, alarm 5197 is
issued.
If the ready signal is not returned within a fixed period of time, alarm 5198
is issued.
Check that the FSSB–related parameters are set correctly.
Check the power supplies of the servo amplifiers connected to the FSSB.
Replace the axis control cards on the CNC.
Replace the optical cables and servo amplifiers connected to the FSSB,
one at a time, to identify the defective item.
See Section 8.14 for explanations about the mounting location of the axis
control card.
D Checking the parameter
settings
D Power supplies of the
servo amplifiers
D Replacing the axis
control cards, optical
cables, and servo
amplifiers