B–64115EN/01
1. DISPLAY AND OPERATION
33
[ SELECT ][ RETURN ][ CLEAR ][ ][ ]
SYSTEM ALARM HISTORY O1234 N12345
1 2002–03–13 12:13:19
930 CPU INTERRUPT
2 2002–03–11 07:23:07
900 ROM PARITY
3 2002–02–27
973 NON MASK INTERRUPT
EDIT **** *** *** 08:20:52
[ ][ ][ NMIHIS ][ ][ ]
This soft key displays the details of a system alarm.
Procedure
1 Press the [(OPRT)] soft key on the system configuration screen.
2 By using the cursor keys
PAGE
PAGE
, move the cursor to the system
alarm number whose details are to be displayed.
3 Press the [SELECT] soft key.
4 The details of the selected system alarm are displayed.
This soft key clears all system alarm information stored.
When bit 4 (OPC) of parameter No. 3110 is set to 1, this soft key is
displayed. When bit 4 (OPC) of parameter No. 3110 is set to 0, this soft
key is not displayed.
Procedure
1 Set bit 4 (OPC) of parameter No. 3110 to 1.
2 Press the [(OPRT)] soft key on the system configuration screen.
3 Press the [CLEAR] soft key.
4 Information about all of the three system alarms stored is cleared.
Pressing the [RETURN] soft key while system alarm history screen
(detail screen) is displayed returns the screen display to the system alarm
list screen.
[SELECT] soft key
[CLEAR] soft key