B-65262EN/03 SPECIFICATIONS FOR THE αiS/αi SERIES 6.BUILT-IN BRAKE
- 103 -
6.2.3 Recommended Parts in Brake Circuits
The following table lists the recommended parts to be used as
components of a brake circuit and their specifications.
Models α
αα
α2is to α
αα
α50is and α
αα
α1i to α
αα
α40i
Name Model No.
Name of
Manufacturer
Specifications
FANUC
Procurement
Dwg. No.
Rectifier
D3SB60
(Note 1)
SHINDENGEN
ELECTRIC MFG.
CO., LTD.
Withstand voltage 400 V min.
Maximum output current: 2.3 A (with no fin)
A06B-6050-K112
Switch - -
Rated load capacity (resistance load)
250VAC 10A / 30VDC 10A or more
-
Spark
killer
XEB0471
OKAYA ELECTRIC
IND. CO., LTD.
47Ω / 0.1µF
Withstand voltage 400 V min.
-
Surge
absorber
ERZV10D820
Matsusihita Electric
Industrial Co., Ltd.
Varistor voltage 82V
Max. allowable voltage 50VAC
-
NOTE
1 At an ambient temperature of 20°C, the temperature
of the rectifier rises to about 60°C when one brake
axis is used or to about 90°C when two brake axes
are used. Use a radiator fin as required.
Models α
αα
α100is to α
αα
α200is
Name Model No.
Name of
Manufacturer
Specifications
FANUC
Procurement
Dwg. No.
Rectifier
D3SB60
(Note 2)
SHINDENGEN
ELECTRIC MFG.
CO., LTD.
Withstand voltage 400 V min.
Maximum output current: 2.3 A (with no fin)
A06B-6050-K112
Switch - -
Rated load capacity (resistance load)
250VAC 20A / 30VDC 20A or more
-
Spark
killer
XEB0471
OKAYA ELECTRIC
IND. CO., LTD.
47Ω / 0.1µF
Withstand voltage 400 V min.
-
Surge
absorber
ERZV10D820
Matsusihita Electric
Industrial Co., Ltd.
Varistor voltage 82V
Max. allowable voltage 50VAC
-
NOTE
2 Use a radiator fin. In addition, use one brake axis per
rectifier.