B-70264EN/02 4.MAINTENANCE
- 43 -
(4) Parameter setting
(a) If the screen is not displayed even after screen manipulation
Check the settings of the following parameters and change them as
appropriate.
i) Press the <SYSTEM> operation key on the CNC to select the
parameter screen.
ii) Check that bit 0 of parameter No. 15160 (MNT) is set to "1".
iii) If it is not set to "1", set bit 0 of parameter No. 15160 (MNT) to
"1" referring to "Setting Parameters" in Chapter 6.
iv) Return "PARAMETER WRITE" to "DISABLE".
#7 #6 #5 #4 #3 #2 #1 #0
15160 MDS MNT
MNT
0 : Does not display the laser maintenance screen.
1 : Displays the laser maintenance screen.
MDS
0 : Disables data input on the laser maintenance screen.
1 : Enables data input on the laser maintenance screen.
(b) Resetting an operation time
After an operation time has reached the corresponding set time and
you have conducted maintenance, you may want to reset the operation
time to 0. To do this, follow the procedure below.
i) Set bit 1 of parameter No. 15160 (MDS) to "1" referring to
"Setting Parameters" in Chapter 6.
ii) Display the component operation time display screen, move the
cursor to the desired operation time field, and enter 0. The
operating time is reset.
iii) After resetting, return bit 1 of parameter No.15160 to "0" and
return "PARAMETER WRITE" to "DISABLE".