5. TOOL FUNCTION (T FUNCTION)
B–63683EN/01
102
O0100 ; O9500 ;
N1 G92 X1800. Y1500. ; N10 #100 = 1.
N2 G90 G00 X1000. Y1000. T400 ; N20 IF [#5001 EQ 0. ] GOTO 50 ;
N3 G65 P9500 X500. Y500. T500 ; N30 G90 G00 X#24 Y#25 T#20 ;
N4 G72 X100. Y100. ; N40 GOTO 60 ;
N5 G26 I10. J0 K4 T600 ; N50 T#100 ;
L N60 M99 ;
The sample macro program is executed in the following sequence: N10,
N20, N50, then N60. Pre–read T codes for T400, T1, and T600 are output
in this order.
The G10 command is also processed before being stored.
[Classification] Output signal
[Function] Informs a pre–issued T code has been specified.
[Output condition] Refer to the item of “output condition” and “basic procedure”
[Classification] Input signal
[Function] Informs that processing a pre–issued T code has been completed.
[Operation] Refer to the item of “Operation” and “Basic procedure”.
Examples
Signal
Pre–issued T code signal
BT00 – BT31
<F246 – F249>
Pre–issued T code
strobe signal
BTF<F232#1>
Pre–issued T code
complete signal
BTFIN<G248#1>