B–62444E–1/04
14. BATCH DATA INPUT/OUTPUT
FUNCTION
OPERATION
235
NOTE
1 When a one–path lathe is used, the data selection menu for
tool post 2 is not displayed.
2 When an input/output unit other than the FANUC Cassette
Adaptor is used, [NC PARAM], [OTHERS], and [NC HD2
PARAM] are not displayed.
(7) When an external input/output unit other than the FANUC Cassette
Adaptor is used, perform read data preparation (such as that done
when searching for the start of data).
When the FANUC Cassette Adaptor is used, the user need not
perform this preparation: the data is called automatically.
(8) Press [NC PARAM] to read the NC parameters for tool post 1. Press
[NC HD2 PARAM] to read the NC parameters for tool post 2.
Press [OTHERS] to read data other than the NC parameters.
Each selected type of data is indicated by displaying the data type
name in reverse characters (in green). When the input of data other
than the NC parameters is specified, the data types actually read
cannot be identified beforehand; all data type names are displayed
in reverse characters (in green).
NOTE
To cancel data read, press [PRE–PG]. The original screen
is displayed.
(9) When [EXEC] is pressed, the following screen appears.
<
EXEC REALLY? YES[EXEC] NO[CANCEL]
I/O
SET UP
EXEC CANCEL
(10) Press [EXEC] to start data input. Press [CANCEL] tocancel data
input.
If several types of data, other than the NC parameters, are output as a batch
beforehand, those types of data can also be read as a batch.
During data input, INPUT blinks in the lower–right corner of the screen.
Data being read is indicated by its data type name, blinking in reverse
video (in yellow). Data that has been read normally is indicated by
displaying the data type name in light blue. When the input of data
terminates with an error, the data type name is displayed in red.
(11) Upon the completion of data input, press [
] to display the main
menu screen.