B–63610EN/01
4. DESCRIPTION OF PARAMETERS
131
3141
Machine name loader name (1st character)
3142
Machine name loader name (2nd character)
3143
Machine name loader name (3rd character)
3144
Machine name loader name (4th character)
3145
Machine name loader name (5th character)
3146
Machine name loader name (6th character)
3147
Machine name loader name (7th character)
[Data type] Byte
Set the machine/loader name by specifying character codes.
When the loader control function is used, a name consisting of up to seven
characters (arbitrary character string consisting of numerics, alphabetics,
and/or symbols) can be displayed in the status display line on the screen,
to indicate whether the currently displayed screen is for the machine or for
the loader.
NOTE
1 These parameters are valid when the loader control
function is used.
2 Set the parameters for the machine and loader separately.
3 For details of character codes, see Appendix A.
[Example] When the names of machine and loader are specified as NC and
LOADER, respectively.
(1) Setting for machine (2) Setting for loader
Parameter 3141 = 78 (N) Parameter 3141 = 76 (L)
Parameter 3142 = 67 (C) Parameter 3142 = 79 (O)
Parameter 3143 = 32 (Space) Parameter 3143 = 65 (A)
Parameter 3144 = 32 (Space) Parameter 3144 = 68 (D)
Parameter 3145 = 32 (Space) Parameter 3145 = 69 (E)
Parameter 3146 = 32 (Space) Parameter 3146 = 82 (R)
Parameter 3147 = 32 (Space) Parameter 3147 = 32 (Space)