4. DESCRIPTION OF PARAMETERS
B–63610EN/01
148
#7
C07
3406
#6 #5
C05
C05
#4
C04
C04
#3
C03
C03
#2
C02
C02
#1
C01
C01
#0
C07
3407
C14
C14 C13
C11
C11
C10
C10 C09
C08
C08C15
3408
C19 C18 C17
C16
C16
CFH
3409
CFH
[Data type] Bit
Cxx (xx: 01 to 19) When bit 6 (CLR) of parameter No.3402 is 1, the reset button on the MDI
panel, the external reset signal, the reset and rewind signal, or emergency
stop will,
0 : Clear the G code with group number xx.
1 : Not clear the G code with group number xx.
CFH When bit 6 (CLR) of parameter No.3402 is 1, the reset button on the MDI
panel, the external reset signal, the reset and rewind signal, or emergency
stop will,
0 : Clear F codes, H codes (for the M series), D codes (for the M series),
and T codes (for the T series).
1 : Not clear F codes, H codes (for the M series), D codes (for the M
series), and T codes (for the T series).
3410 Tolerance of arc radius
[Data type] 2–word
[Unit of data]
Increment system IS–A IS–B IS–C Unit
Millimeter input 0.01 0.001 0.0001 mm
Inch input 0.001 0.0001 0.00001 inch
[Valid data range] 1 to 99999999
When a circular interpolation command (G02, G03) is executed, the
tolerance for the radius between the start point and the end point is set. If
the difference of radii between the start point and the end point exceeds the
tolerance set here, a P/S alarm No.20 is informed.
NOTE
When the set value is 0, the difference of radii is not checked.
In the HPCC mode, a check is made for a difference in the arc
radius even if the set value is “0” (with allowable limit = 0).