B–63610EN/01
4. DESCRIPTION OF PARAMETERS
151
Example: Relationships between specified value and S code
output/alarm
S200.5 –> S code output value = 201
S200.2 –> S code output value = 200
S200.12 –> P/S007 alarm is raised.
CCK If chamfering or corner R is enabled and if the end point specified in an arc
command is not complete,
0 : No alarm is raised.
1 : An alarm (P/S058 alarm) is raised.
This parameter specifies whether an alarm is raised if chamfering or
corner R is enabled, if the end point specified in an arc command is not
complete, and if an address is omitted.
If the end point is omitted in an arc command, chamfering or corner R may
affect the omitted point, and the operation may not be performed as
intended by the programmer. If this parameter is specified, an alarm can
be raised for that type of program execution.
NBN If bit 0 (NOP) of parameter No. 3404 is set to 1, a block including just N
(sequence number) is:
0 : Ignored.
1 : Not ignored but handled as a single block.
#7
3453
#6 #5 #4 #3 #2 #1 #0
CRD
[Data type] Bit
CRD If the functions of chamfering or corner R and direct drawing dimension
programming are both enabled,
0 : Chamfering or corner R is enabled.
1 : Direct drawing dimension programming is enabled.
If the functions of chamfering or corner R and direct drawing dimension
programming are both specified, this parameter specifies which function
is used.
This parameter is displayed also on the setting screen. (“CHAMFERING/
DIRECT DRAWING DIMENSION PROGRAMMING”) The function
to be enabled can be changed from the setting screen or parameter screen.
#7
3455
#6 #5 #4 #3 #2 #1 #0
AXD
[Data type] Bit axis
AXD If a decimal point is omitted for an address with which a decimal point can
be used, the value is determined:
0 : In accordance with the least input increment.
1 : In millimeters, inches, or seconds. (calculator–type decimal point
input)