
B–63610EN/01
4. DESCRIPTION OF PARAMETERS
237
5261
Linear acceleration/deceleration time constant for the spindle and tapping axis
(first–stage gear)
5262
Linear acceleration/deceleration time constant for the spindle and tapping axis
(second–stage gear)
5263
Linear acceleration/deceleration time constant for the spindle and tapping axis
(third–stage gear)
5264
Linear acceleration/deceleration time constant for the spindle and tapping axis
(fourth–stage gear)
5265
Linear acceleration/deceleration time constant for the second spindle and tap-
ping axis (first–stage gear)
5266
Linear acceleration/deceleration time constant for the second spindle and tap-
ping axis (second–stage gear)
[Data type] Word
[Unit of data] ms
[Valid data range] 0 to 4000
Each of these parameters is used to set a linear acceleration/deceleration time
constant for the spindle of each gear and the tapping axis in rigid tapping.
Set the period required to reach each maximum spindle speed (parameters
No.5241 through No.5248). The set time constant, multiplied by the ratio
of a specified S value to a maximum spindle speed, is actually used as a
time constant.
NOTE
When rigid tapping is performed using the second and third
spindles
• When the SPR parameter (bit 1 of parameter No.5204)
is set to 0, the settings of parameters No.5261 and
No.5262 are applied to the second spindle, as well as to
the first spindle.
• When the SPR parameter (bit 1 of parameter No.5204)
is set to 1, the settings of parameters No.5265 and
No.5266 are applied to the second spindle.