4. DESCRIPTION OF PARAMETERS
B–63610EN/01
248
5353
Positional deviation limit imposed while the spindle is stopped in rigid tapping
using the second spindle
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter is used to set a positional deviation limit imposed while
the spindle is stopped in rigid tapping using the second spindle.
NOTE
This parameter is enabled when the SPR parameter (bit 1
of parameter No.5204) is set to 1.
5381
Override value for rigid tapping return
[Data type] Byte
[Units of data] 1% or 10%
[Valid data range] 0 to 200
Set the override value to be applied during rigid tapping return.
When 0 is set, no override is applied.
NOTE
This parameter is valid when bit 4 (DOV) of parameter No.
5200 is set to 1. If bit 3 (OVU) of parameter No. 5201 is set
to 1, 10% is set as the units of data. Thus, an override of
up to 2000% can be applied during extraction.
5382
Amount of return for rigid tapping return
[Data type] 2–word
[Unit of data] Input increments
[Valid data range] 0 to 99999999
During rigid tapping return for the machining return and restart function,
the tool can be pulled out, along the tapping axis, going beyond the stored
rigid tapping start position by the amount specified with this parameter.