B–63610EN/01
4. DESCRIPTION OF PARAMETERS
267
#7
6131
#6 #5 #4 #3 #2 #1 #0
EOA OAD
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit axis
OAD The function for positioning by optimul acceleration (when rapid traverse
is specified in automatic operation, the function adjusts the rapid traverse
rate, time constant, and loop gain to one of seven levels, according to the
amount of travel for the block) is:
0 : Not used.
1 : Used.
EOA For a movement along the PMC axis, the function for positioning by
optimum acceleration is:
0 : Disabled.
1 : Enabled.
Bit 0 (OAD) of parameter No. 6131 must also be set to 1.
#7
6132
#6 #5 #4 #3 #2 #1 #0
ILP
[Data type] Bit
ILP For the function for positioning by optimum acceleration, loop gain
switching is:
0 : Performed.
1 : Not performed.
6136
Distance D1 to the first stage of positioning by optimum acceleration for each axis
6137
Distance D2 to the second stage of positioning by optimum acceleration for each axis
6138
Distance D3 to the third stage of positioning by optimum acceleration for each axis
[Data type] 2–word axis
[Unit of data]
Increment system IS–A IS–B IS–C Unit
Metric machine 0.01 0.001 0.0001 mm
Inch machine 0.01 0.001 0.0001 inch
Rotation axis 0.01 0.001 0.0001 deg
[Valid data range] 0 to 99999999
These parameters set the distances to the first to third stages of positioning
by optimum acceleration for each axis.
4.33
PARAMETERS OF
POSITIONING
BY OPTIMUM
ACCELERATION