4. DESCRIPTION OF PARAMETERS
B–63610EN/01
268
Set the positioning distances used when the function for 4–stage
switching of the rapid traverse rate, time constant, and loop gain based on
positioning distance is used.
6141
Distance D1 for level 1 (metric input)
6142
Distance D2 for level 2 (metric input)
6143
Distance D3 for level 3 (metric input)
6144
Distance D4 for level 4 (metric input)
6145
Distance D5 for level 5 (metric input)
6146
Distance D6 for level 6 (metric input)
[Data type] 2–word
[Unit of data]
Increment system IS–A IS–B IS–C Units
Linear axis (inch input) 0.01 0.001 0.0001 mm
Rotation axis 0.01 0.001 0.0001 deg
[Valid data range] 0 to 99999999
These parameters set the positioning distances used when the function for
adjusting the rapid traverse rate, time constant, and loop gain to one of
seven levels according to the positioning distance is used. (The settings
are common to all axes.)
6151
Distance D1 to the first stage (for inch input)
6152
Distance D2 to the second stage (for inch input)
6153
Distance D3 to the third stage (for inch input)
6154
Distance D4 to the fourth stage (for inch input)
6155
Distance D5 to the fifth stage (for inch input)
6156
Distance D6 to the sixth stage (for inch input)