4. DESCRIPTION OF PARAMETERS
B–63610EN/01
22
[Valid data range] 2 to 52
This parameter specifies the station address of the CNC when the CNC is
connected via the DNC1 interface using multipoint connection.
0143 Time limit specified for the timer monitoring a response (DNC2 interface)
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Byte
[Unit of data] S
[Valid data range] 1 to 60 (The standard setting is 3.)
0144 Time limit specified for the timer monitoring the EOT signal (DNC2 interface)
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Byte
[Unit of data] S
[Valid data range] 1 to 60 (The standard setting is 5.)
0145 Time required for switching RECV and SEND (DNC2 interface)
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Byte
[Unit of data] S
[Valid data range] 1 to 60 (The standard setting is 1.)
0146 Number of times the system retries holding communication (DNC2 interface)
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Byte
[Unit of data] S
[Valid data range] 1 to 10 (The standard setting is 3.)
Set the maximum number of times the system retries holding
communication with the remote device if the remote device uses an
invalid protocol in the data–link layer or the remote device does not
respond to the request.