4. DESCRIPTION OF PARAMETERS
B–63610EN/01
280
#7
6400
#6 #5 #4 #3
HM8
#2
HM5
#1
HFW
#0
HRP
[Data type] Bit
HRP With the retrace function by the manual handle, the rapid traverse rate is
clamped, assuming that:
0 : An override of 10% is used.
1 : An override of 100% is used.
HFW With the retrace function by manual handle, program execution can be
performed:
0 : In both forward and backward directions.
1 : Only in the forward direction.
HM8, HM5
HM8 HM5 M code group setting
0 0 Standard (20 groups of four)
0 1 16 groups of five
1 0 10 groups of eight
These parameters set the number of M code groups and the number of M
codes in each group.
(See explanations of parameters Nos. 6411 to 6490.)
When 16 groups of five are used, the meanings of parameters are changed
as follows:
Group A No.6411(1) to No.6415(5)
Group B No.6416(1) to No.6420(5)
:
Group P No.6486(1) to No.6490(5)
When 10 groups of eight are used, they are changed as follows:
Group A No.6411(1) to No.6418(8)
Group B No.6419(1) to No.6426(8)
:
Group J No.6483(1) to No.6490(8)
6410
Travel distance per pulse generated from the manual pulse generator for the
retrace function by the manual handle
[Data type] Byte
[Unit of data] 1%
[Valid data range] 0 to 100
This parameter sets the travel distance per pulse generated from the
manual pulse generator for the retrace function by the manual handle.
This function moves (or dwells) the tool by ([this parameter setting] ×
[handle magnification]/[pulse of manual pulse generator]).
4.37
PARAMETERS OF
RETRACING BY THE
MANUAL HANDLE