4. DESCRIPTION OF PARAMETERS
B–63610EN/01
310
#7
7103
#6 #5 #4
IBH
#3
HIT
#2
HNT
#1
RHD
#0
[Data type] Bit
RHD By a reset, the amount of manual handle interruption is:
0 : Not canceled.
1 : Canceled.
NOTE
This parameter is valid when bit 2 (IHD) of parameter No.
7100 is set to 1.
HNT The manual handle feed/incremental feed magnification is:
0 : Multiplied by 1.
1 : Multiplied by 10.
HIT The manual handle interruption magnification is:
0 : Multiplied by 1.
1 : Multiplied by 10.
IBH Manual handle feed for the β servo unit using an I/O link is:
0 : Disabled.
1 : Enabled.
7110 Number of manual pulse generators used
[Data type] Byte
[Valid data range] 1 or 2 (T series), 3 (M series)
This parameter sets the number of manual pulse generators.
7113 Manual handle feed magnification m
[Data type] Word
[Unit of data] One time
[Valid data range] 1 to 127
This parameter sets the magnification when manual handle feed
movement selection signals MP1 and MP2 are set to 0 and 1.