B–63610EN/01
4. DESCRIPTION OF PARAMETERS
313
7181 First withdrawal distance in reference position setting with mechanical stopper
[Data type] 2–word axis
[Unit of data]
Increment system IS–A IS–B IS–C Unit
Millimeter machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
[Valid data range] –99999999 to 99999999
When the reference position setting with mechanical stopper is used, this
parameter sets a distance an axis, along which withdrawal is performed
after the mechanical stopper is hit (distance from the mechanical stopper
to the withdrawal point).
NOTE
Set the same direction as that set in bit 5 (ZMIx) of parameter
No. 1006. Cycle operation cannot be started if the opposite
direction is set.
7182 Second withdrawal distance in reference position setting with mechanical stopper
[Data type] 2–word axis
[Unit of data]
Increment system IS–A IS–B IS–C Unit
Millimeter machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
[Valid data range] –99999999 to 99999999
When the reference position setting with mechanical stopper is used, this
parameter sets a distance an axis, along which withdrawal is performed
after the mechanical stopper is hit (distance from the mechanical stopper
to the withdrawal point).
NOTE
Set the same direction as that set in bit 5 (ZMIx) of parameter
No. 1006. Cycle operation cannot be started if the opposite
direction is set.
4.45
PARAMETERS OF
REFERENCE
POSITION SETTING
WITH MECHANICAL
STOPPER