4. DESCRIPTION OF PARAMETERS
B–63610EN/01
28
#7
NFD0231
#6 #5 #4 #3
ASI
#2 #1 #0
SB2
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type]
SB2 Number of stop bits
0: 1 bit
1: 2 bits
ASI Data input code
0: IEA or ISO (automatic recognition)
1: ASCII Code
NFD When data is out, feed holes are
0: Output before and after data section
1: Not output
0233 Baud rate (DNC1 interface #2)
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Byte
[Valid data range] 1 to 15
Set value Baud rate (bps)
7
8
9
10
Set value Baud rate (bps)
11
12
13
9600
38400
14
8640015
300
600
1200
2400
4800
19200
76800
Set value Baud rate (bps)
1
2
3
4
5
50
100
110
150
200
6
Baud rate
0241 Mode of connection between the host and CNC (DNC1 interface #2)
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Byte
[Valid data range] 1 to 2
This parameter sets the mode of connection between the host and CNC.
Setting Mode
1 Point–to–point mode
2 Multipoint mode
4.5
PARAMETERS OF
DNC1 INTERFACE