4. DESCRIPTION OF PARAMETERS
B–63610EN/01
342
8311 Axis number of master axis in synchronous control
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Byte axis
<For the T Series>
Select a master axis and slave axis in simple synchronous control. Set a
master axis number with a slave axis. For the parameters for the first axis
through the fourth axis of parameter No.8311, set the following:
Units digit of the parameter for the first axis –>
Set the axis number of a master axis for the first axis.
Tens digit of the parameter for the first axis –>
Set the axis number of a master axis for the second axis.
Units digit of the parameter for the second axis –>
Set the axis number of a master axis for the third axis.
Tens digit of the parameter for the second axis –>
Set the axis number of a master axis for the fourth axis.
Units digit of the parameter for the third axis –>
Set 0.
Tens digit of the parameter for the third axis –>
Set 0.
Units digit of the parameter for the fourth axis –>
Set 0.
Tens digit of the parameter for the fourth axis –>
Set 0.
Number Tens digit Units digit
First axis Second axis First axis
Second axis Fourth axis Third axis
Note that the axis number settings are as follows:
0 –> First axis, 1 –> Second axis, 2 –> Third axis, 3 –> Fourth axis
Example: If the master and slave axes are assigned as the third and fourth
axes, respectively, set up as follows:
No. 8311 First: 00
Second: 20
Third: 00
Fourth: 00
NOTE
For an axis for which 0 is set, the first axis serves as the
master axis. So, when the control signal for the axis is set
to 1, the first axis serves as a master axis, and synchronous
control is exercised.