4. DESCRIPTION OF PARAMETERS
B–63610EN/01
38
XIK When LRP, bit 1 of parameter No.1401, is set to 0, namely, when
positioning is performed using non–linear type positioning, if an
interlock is applied to the machine along one of axes in positioning,
0: The machine stops moving along the axis for which the interlock is
applied and continues to move along the other axes.
1: The machine stops moving along all the axes.
IDG When the reference position is set without dogs, automatic setting of the
IDGx parameter (bit 0 of parameter No.1012) to prevent the reference
position from being set again is:
0 : Not performed.
1 : Performed.
#7
IPR
1004
IPR
#6 #5 #4 #3 #2 #1
ISC
ISC
#0
ISA
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
ISA, ISC The least input increment and least command increment are set.
ISC ISA
Least input increment and least command
increment
Symbol
0 0 0.001 mm, 0.001 deg, or 0.0001 inch IS–B
0 1 0.01 mm, 0.01 deg, or 0.001 inch IS–A
1 0 0.0001 mm, 0.0001 deg, or 0.00001 inch IS–C
NOTE
IS–A cannot be used at present.
IPR Whether the least input increment for each axis is set to a value 10 times as
large as the least command increment is specified, in increment systems
of IS–B or IS–C at setting mm.
0: The least input increment is not set to a value 10 times as larg as the
least command increment.
1: The least input increment is set to a value 10 times as large as the least
command increment.
If IPR is set to 1, the least input increment is set as follows:
Input increment Least input increment
IS–B 0.01 mm, 0.01 deg, or 0.0001 inch
IS–C 0.001 mm, 0.001 deg, or 0.00001 inch
NOTE
For IS–A, the least input increment cannot be set to a value
10 times as large as the least command increment.
The least input increment is not multiplied by 10 also when
the calculator–type decimal point input (bit 0 (DPI) of