B–63610EN/01
4. DESCRIPTION OF PARAMETERS
53
#7
1301
#6 #5 #4
OF1
#3 #2 #1 #0
DLM
OTS OF1 DLM
[Data type] Bit
DLM The stored stroke limit switching signal for each axial direction is:
0: Enabled.
1: Disabled.
OF1 If the tool is moved into the range allowed on the axis after an alarm is
raised by stored stroke check 1,
0: The alarm is not canceled before a reset is made.
1: The OT alarm is immediately canceled.
CAUTION
In the cases below, the automatic release function is
disabled. To release an alarm, a reset operation is required.
1 When a setting is made to issue an alarm before a stored
stroke limit is exceeded (bit 7 (BFA) of parameter No.
1300)
2 When an another overtravel alarm (such as stored stroke
check 2, stored stroke check 3, and interference check) is
already issued
3 When an overtravel alarm is already issued with the
high–precision contour control function or the chopping
function in the M series
OTS If a stored stroke limit alarm is raised by setting bit 7 (BFA) of parameter
No. 1300 to 1, the axial movement stops:
0: Before the boundary of stored stroke check.
1: On the boundary of stored stroke check.
CAUTION
To enable this parameter, the manual linear/circular
interpolation function is required. If this function is not
provided, this parameter setting is ignored.
#7
1310
#6 #5 #4 #3 #2 #1
OT3x
#0
OT2x
OT2x
[Data type] Bit axis
OT2x Whether stored stroke check 2 is checked for each axis is set.
0: Stored stroke check 2 is not checked.
1: Stored stroke check 2 is checked.
OT3x Whether stored stroke check 3 is checked for each axis is set.
0: Stored stroke check 3 is not checked.
1: Stored stroke check 3 is checked.