B-63324EN-1/03 OPERATION 4.AUTOMATIC OPERATION
- 119 -
4.4 SELECTION OF EXECUTION PROGRAMS
This section describes how to select a program to be executed
(execution program) from among multiple programs and how to rewind
the program to the top of the program.
4.4.1 Program Number Search
Search for the execution program from among currently stored
programs by its program number.
Program number search is performed in the program screen.
- Mode selection
Select the MEMORY mode.
- Number search
Method 1
(1) Key in address <O>.
(2) Key in a program number to be searched.
(3) Press soft key [FRWRD SEARCH] or [BKWRD
SEARCH].
Method 2
(1) Press soft key [FRWRD SEARCH] or [BKWRD
SEARCH].
(2) Key in address <O>.
(3) Key in a program number to be searched.
(4) Press soft key [EXEC].
Method 3
(1) Press soft key [FRWRD SEARCH] or [BKWRD
SEARCH].
(2) Press soft key [(PROG#)]. "0" is automatically keyed in.
(3) Key in a program number to be searched.
(4) Press soft key [EXEC].
Method 4 To select the next program:
(1) Press soft key [FRWRD SEARCH].
(2) Press soft key [NEXT PROG].
Method 5 To select the previous program:
(1) Press soft key [BKWRD SEARCH].
(2) Press soft key [NEXT PROG].
NOTE
1 If a program having the specified number is not
found, you are informed of this on the program
screen.
2 Program number search is enabled only in the
memory operation mode. Program number search is
not possible in the DNC operation mode.