B-63324EN-1/03 OPERATION 7.ALARMS AND SELF DIAGNOSTC FUNCTIONS
- 217 -
NOTE
1 An already set item name cannot be overwritten by an
item name selected from the item selection menu
screen. Delete the existing item name, then set a
new item name.
2 When the item of the battery for the control unit or the
battery for the absolute-position detector is selected
and set, its life time, like other data, is managed by
using the life time set on the periodic maintenance
screen. Therefore, life time management is not
related to the battery alarm detected by the system.
- Input format
x x x x x x x * x x x x x x x x * x x x x x x x x
Alphanumeric Kanji/hiragana Alphanumeric
Describe alphanumeric characters directly. Kanji and hiragana
character code must be enclosed by an asterisk (*). Either FANUC
code or JIS code can be selected as the character code by setting bit 6
(JIS) of parameter No. 2286. A name can consist of up to 24
alphanumeric characters (one kanji or hiragana character is counted as
two alphanumeric characters).
Example: To enter "TABLE," specify the following:
FANUC code :TABLE*13AE08DA0738*
JIS code :TABLE*3D61336A4C7D*
NOTE
Symbols *, [, ], (, ), and ; cannot be included in an item
name.
Setting the service life
1)
Position the cursor to the desired service life by using
the cursor keys .
2) Key in a time. The set value must be between 0 and 999999
(hours).
3)
Press the
[INPUT]
soft key or the key.
The service life and remaining time are set to the same value, and
the count type is initialized.
4) When a time is keyed in, after which the [+INPUT] soft key is
pressed, the set value is added to the existing service life. The
value is also added to the remaining time.
INPUT