9.SETTING AND DISPLAYING DATA OPERATION B-63324EN-1/03
- 374 -
Offset data increment system
As an offset, a number with or without a decimal point can be entered.
The increment system of an offset depends on the parameter settings, as
indicated below.
Parameter Offset value increment system (valid data range)
OFE OFD OFC OFA Metric input Inch input
0 0 0 1 0.01
(±9999.99)
0.001
(±999.999)
0 0 0 0 0.001
(±9999.999)
0.0001
(±999.9999)
0 0 1 0 0.0001
(±9999.9999)
0.00001
(±999.99999)
0 1 0 0 0.00001
(±9999.99999)
0.000001
(±999.999999)
1 0 0 0 0.000001
(±999.999999)
0.0000001
(±99.9999999)
OFA : Bit 0 of parameter No. 6002
OFC : Bit 1 of parameter No. 6002
OFD : Bit 0 of parameter No. 6004
OFE : Bit 0 of parameter No. 6007
Adding a tool number
Method 1
(1) Position the cursor to the data immediately preceding the
display number you want to add.
(2) Press the [INSERT] soft key.
(3) Press the [(T#)] soft key.
(4) Enter a tool number.
(5) Press the [EXEC] soft key.
Method 2
(1) Position the cursor to the data immediately preceding the
display number you want to add.
(2) Press the [INSERT] soft key.
(3) Press the
T
address key.
(4) Enter a tool number.
(5) Press the [EXEC] soft key.
Method 3
(1) Position the cursor to the data immediately preceding the
display number you want to add.
(2) Press the
T
address key.
(3) Enter a tool number.
(4) Press the [INSERT] soft key.
(Example) Adding tool number 600 between display number 1 and
display number 2