9.SETTING AND DISPLAYING DATA OPERATION B-63324EN-1/03
- 386 -
Setting data
1) Select MDI mode.
2) With the cursor keys
, position the cursor to
the item you want to set.
3) Select a setting with the [SELECT+] and [SELECT-] soft keys.
NOTE
1 For channels whose device numbers (parameter No.
5001 to No. 5003, No. 5013) are not set, the following
default parameter sets are selected:
RS-232C channel 1: Parameter set 1 (Nos. 5110,
5111, 5112)
RS-232C channel 2: Parameter set 2 (Nos. 5120,
5121, 5122)
RS-232C channel 3: Parameter set 3 (Nos. 5130,
5131, 5132)
RS-422 channel 1: Parameter set 4 (Nos. 5140,
5141, 5142)
2 If a value that falls outside the specifiable range is
specified in a stop bit or baud rate parameter, the
following defaults are internally selected and
displayed on the screen, even though the defaults are
not reflected in the parameter:
Stop bit: 2
Baud rate: 9 (4800 bps)
3 If a value that falls outside the specifiable range is
specified in a device specification parameter,
"UNKNOWN" is indicated.
Floppy directory screen
Pressing the [RS232C] soft key switches the display screen to the
floppy directory screen. The floppy directory screen enables data
input/output through a serial interface channel set with the F.G input
device item, F.G output device item, B.G input device item, or B.G
output device item. For details, see Section II-10.12, "Floppy Directory
Screen."