10.DISPLAY OPERATION B-63324EN-1/03
- 528 -
NOTE
1 When torque data output method 1 (when neither
output file name nor file number is specified) is used
to output torque data onto a memory card,
FNTRQSNS.DAT is assigned as the file name.
2 Torque data cannot be output when:
- There is no torque data stored.
- The torque sensing command signal is 1.
- The statistics calculation start signal is 1.
- The store counter clear signal is 1.
- Torque data input procedure
Method 1 (when neither file name nor file number of an input file is
specified)
(1) Press the soft key [READ].
(2) Press the soft key [EXEC].
Method 2 (when an input file is specified with a file name)
(1) Press the soft key [READ].
(2) Press the soft key ["FILE NAME].
(3) Enter a file name.
(4) Press the soft key [FILE NAME"].
(5) Press the soft key [EXEC].
Method 3 (when an input file is specified with a file number 1)
(1) Press the soft key [READ].
(2) Press the soft key [(FILE#)].
(3) Enter a file number.
(4) Press the soft key [EXEC].
Method 4 (when an input file is specified with a file number 2)
(1) Press the soft key [READ].
(2) Press the address key.
(3) Enter a file number.
(4) Press the soft key [EXEC].
Method 5 (when an input file is specified with a file number 3)
(1) Press the address key.
(2) Enter a file number.
(3) Press the soft key [READ].
N
N