22. DISPLAYING AND SETTING DATA
B–63172EN/01
NC FUNCTION
138
The Japanese, English, German, French, Italian, and Spanish are prepared
as display languages. Select the language to be displayed by parameters.
Time is displayed in the hour/minute/second format on each display
screen. Some screens allows display of the year, month, and day.
The custom macro system variable can be used to read the time. The time
will be told through the window at PMC side.
This function displays the integrated power-on time, the integrated cycle
operation time, the integrated cutting time and timer on the cRT display
screen. The integrated cycle operation time, the integrated cutting time
and timer can be altered and preset, using the MDI.
In addition to the above, this function displays the count of the total
number of parts machined, the number of parts required and the number
of parts on the screen. Each time M02, M30 or a parameter set M code
is executed, the count of the total in memory is incremented by 1.
If a program is prepared so as to execute M02, M30 or a parameter set M
code each time one part machining is completed, the number of parts
machined can be counted automatically.
If the count of the number of parts reaches the number of parts required,
a signal is output to the PMC side.
It is possible to change and preset the number of parts required and the
number of parts counted, using MDI.
The number of required parts and the number of counted parts can be read
and written using custom macro variables.
SETTING(TIMER) O0000 N00000
PARTS TOTAL = 0
PARTS REQUIRED = 25
PARTS COUNT = 10
POWER ON = 0H 0M
OPERATING TIME = 0H 0M 0S
CUTTING TIME = 0H 0M 0S
FREE PURPOSE = 0H 0M 0S
CYCLE TIME = 0H 0M 0S
DATE = 1997/09/25
TIME = 16:20:30
>_
MDI **** *** *** 16:20:30
[ OFFSET ][ SETTING ][ ][ ][ (OPRT) ]
22.2
LANGUAGE
SELECTION
22.3
CLOCK FUNCTION
22.4
RUN TIME & PARTS
NUMBER DISPLAY