B–63172EN/01
22. DISPLAYING AND SETTING DATA
NC FUNCTION
143
On the spindle setting screen, parameters required for standard
initialization of the serial spindle are listed. The parameters can also be
set. This screen is only for the main spindle connected to the first
amplifier.
SPINDLE SETTING O0000 N00000
GEAR SELECT :1
SPINDLE :1
(PARAMETER)
GEAR RATIO 50
MAX SPINDLE SPEED 3000
MAX MOTOR SPEED 6000
MAX C AXIS SPEED 100
>_
MDI **** *** *** 09:36:48
[ SP.SET ][ SP.TUN ][ SP.MON ][ ][ (OPRT) ]
On the spindle adjustment screen, parameters required for basic
adjustment of the serial spindle and statuses being monitored are listed.
The screen is only for the main spindle connected to the first amplifier.
SPINDLE TUNING O1000 N00000
OPERATION : SYNCHRONIZATION CONTROL
GEAR SELECT : 1
SPINDLE : S11
(PARAMETER) (MONITOR)
PROP.GAIN –2460 MOTOR 100
INT.GAIN 241 SPINDLE 150
LOOP GAIN 3000 POS ERR S1 100
MOTOR VOLT 30 POS ERR S2 50
ZRN GAIN % 100 SYN.ERROR 128
REF.SHIFT 2046
>_
AUTO STAT MTN *** *** 09:36:48
[ SP.SET ][ SP.TUN ][ SP.MON ][ ][ (OPRT) ]
22.7.3
Spindle Setting Screen
22.7.4
Spindle Adjustment
Screen