25. DATA INPUT/OUTPUT
B–63172EN/01
NC FUNCTION
160
When the servo amplifier β series with I/O Link is used as an additional
(slave) axis of the CNC, the power mate CNC manager enables the
display and setting of data from the CNC. Up to eight slave units can be
connected.
The power motion manager supports the following functions:
1) Current position display (absolute/machine coordinate)
2) Parameter display and setting
3) Diagnosis
4) System configuration screen
5) Alarm
POWER MATE CNC MANAGER
SYSTEM CONFIGURATION
1. GROUP1/ β 2. GROUP2/ β
SYSTEM 88A1 01 SYSTEM 88A1 01
3. GROUP3/ β 4. GROUP4/ β
SYSTEM 88A1 01 SYSTEM 88A1 01
SELECT ACTIVE SLAVE[>]
[ POS ][ ][ PUNCH ][ SYSTEM ][ MSG ]
The sample screen shows the data for four units.
The analog input function digitizes an analog signal ranging from –10 DC
to + 10 V applied externally, and outputs the resulting signed 12–bit data
as the F signal of the PMC. The resolution is 4.9 mVo (uninsulated type).
By specifying a parameter, an offset can be applied to an input voltage.
25.5
POWER MATE CNC
MANAGER
25.6
ANALOG INPUT
FUNCTION