B-63173EN/02-12
4/4EDIT
DATE DESIG. DESCRIPTION
FANUC Power Mate – i MODEL D/ H
CONNECTION MANUAL
THE FUNCTION OF INCREMENT SYSTEM IS-C
TITLE
DRAW.NO. CUST.
SHEET
01
000530 New design
IS-A,IS-B IS-C
Metric input Inch input Metric input Inch input
Magnified
by 1
166458mm/min 1664.58inch/mi
n
16645mm/min 166.45inch/min
Magnified
by 10
240000mm/min 9600inch/min 100000mm/min 1664.58inch/min
IS-A,IS-B IS-C
Metric input Inch input Metric input Inch input
Magnified
by 1
65535mm/min 655.35inch/min 6553mm/min 65.53inch/min
Magnified
by 10
240000mm/min 6553.50inch/min 65535mm/min 655.35inch/min
IS-A IS-B IS-C Unit
Metric input
Degree input
0.01 0.001 0.0001 mm
deg
Inch input 0.001 0.0001 0.00001 inch
(1) Rapid traverse(EC0g~
~~
~EC6g:00h)
))
)
(2) Cutting feed-feed per minuteEC0g~
~~
~EC6g:01h)
))
)
(3) Cutting feed-feed per rotation(EC0g~
~~
~EC6g:02h)
))
)
(4) Skip –feed per minute(
((
(EC0g~
~~
~EC6g:03h)
))
)
For these commands, signals EID0g to EID31g are used to specify, in
binary format, the incremental moving distance, according to the input
increment used for the axis.
IS-A IS-B IS-C Unit
Metric input
Degree input
±
±±
±999999.99 ±
±±
±99999.999 ±
±±
±9999.9999 mm
deg
Inch input ±
±±
±99999.999 ±
±±
±9999.9999 ±
±±
±999.99999 inch
Replace the description of the table of " (12) Continuous feed " of the " 3 axis control
feedrate signals EIF0g to EIF15g"
in the chapter " 15 PMC CONTROL FUNCTION" as
follows.
CAUTION
The maximum feedrate depends on whether override is applied or canceled. The following
table lists the maximum feedrate when override is canceled.
Replace the description of the table of the " 4 Axis control data signals EID0g to EID31g" in the
chapter " 15 PMC CONTROL FUNCTION" as follows.
[ Unit of data ]
[Valid data range]