EDT
DATE
A-61050E
3 / 3
DS0100-04
01
2001.Mar.23
Newly registered
DESIG.
DESCRIPTION
TITLE
NO.
PAGE
FANUC Series 16/18
i
-MA, 16/18-MC
Improvement of rigid tapping function
Specifications
3. Parameters
No. #7#6#5#4#3#2#1#0
5203 REF
[Data type] Bit
REF The operation of the rigid tapping is as shown in the following setting.
1 : The feed-forward control and the fine acceleration/deceleration between
Initial-level and R-points are effective.
Moreover, when the rigid tapping is executed in the look-ahead control mode,
the mode is automatically turned on and off.
0 : The feed-forward control and the fine acceleration/deceleration between
Initial-level and R-points are invalid.
Moreover, when the rigid tapping is executed in the look-ahead control mode,
the mode is not automatically turned on and off.
No.
5308 Width of in-position in R-point of tapping axis in rigid tapping
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 0 to 32767
The width of in-position in R-point of the tapping axis (Between from rapid to R-point to
the tapping operation) in rigid tapping can be set.
When a set value is 0, the width of in-position of the tapping axis in rigid tapping is only
setting of No.5300.