A-79619E
Title
Draw
No.
Ed. Date Design Description
Date Sep.10.’04 Design. Apprv.
43/53
page
FANUC Series 30i/31i-MODEL A
Rotation Area Interference Check
Settings for the movement and rotation axes
Group A movement, 1st axis Z-axis Parameter No. 14910=2
Group A movement, 2nd axis X-axis Parameter No. 14911=1
Group A rotation axis B-axis Parameter No. 14912=5
Group B movement, 1st axis A-axis Parameter No. 14913=6
Reference position return
Perform a reference position return on each axis.
Positioning of the rotation axis at the reference rotation angle
Rotate the B-axis so that the rectangles to make interference check group A
become parallel to the X- and Z-axes.
OK OK NG
When the reference rotation angle of the B-axis is determined, set it in the
parameter:
Group A reference rotation angle
Parameter No. 14938 = B-axis machine coordinates