FANUC Series 30i/31i-MODEL A
Rotation Area Interference Check
Settings for interference check group B
Similarly to interference check group A, in the state in which the A-axis is
positioned at the reference rotation angle, measure the data on the rectangles
making up the interference check group and set the measured values in
parameters. Measure the distances from the machine zero point in the same
way as with interference check group A.
Z
2nd axis measurement
1st axis measurement
Machine zero point
Parameter No. 14940 = Rectangle 1 1st axis maximum point distance
Parameter No. 14941 = Rectangle 1 1st axis minimum point distance
Parameter No. 14942 = Rectangle 1 2nd axis maximum point distance
Parameter No. 14943 = Rectangle 1 2nd axis minimum point distance
Parameter No. 14944 = Rectangle 2 1st axis maximum point distance
Parameter No. 14945 = Rectangle 2 1st axis minimum point distance
Parameter No. 14946 = Rectangle 2 2nd axis maximum point distance
Parameter No. 14947 = Rectangle 2 2nd axis minimum point distance
Rotation center of interference check group B
Similarly to rectangle data measurement, measure the center point about
which interference check group B is to rotate, from the A-axis.