Change the Structure of the Safety Cover of LASER C Series for CE Marking Additional Manual Page 1

Additional Manual
Change the structure of the safety cover
of LASER C series for CE Marking
1/4
FANUC LTD
A-81053E-078
Description Design Date Edit.
01 041005 MURAKAMI
Title
Sheet
Draw. No.
Change the structure of the safety cover
of LASER C series for CE Marking
1. Outline
In outer of the shutter unit, the absorber unit, and LD unit of laser C1000-E, C2000-E and
C4000-E for CE Marking, there are the safety cover for the shading of direct light and/or
indirect light that it is visible and/or is invisibility.
We obtained the opinion with "The safety cover of a simple type can be attested compared
with a present type." from the safety attestation organization.
We report changing from the present safety cover to the simple type safety cover adopted
for laser C5000-E and C6000-E for the maintainability improvement.
2. Applied model, and Schedule of applying
Model Schedule
C1000-E
L04910965
C2000-E
L04820970
C4000-E
L04840214
3. Detail of changed content
The structure of the safety cover for CE Marking was changed to the simple type safety
cover adopted for laser C5000-E and C6000-E. Please refer to the next page for externals
of the safety cover.
The present safety cover: This type shades all of he shutter unit, the absorber unit,
and LD unit.
The simple safety cover: This type shades between the shutter unit and the
absorber unit.
4. Confirmation after the transportation
The beam flange of the safety cover for CE Marking is fixed with a small space 2 exists
between the beam cover pipe installed in output mirror holder. At installation after the
transportation, check whether the interference with the beam flange and the beam cover
pipe, and loosening of beam flange installation bolt 1. Please adjust, and tighten when
there are interference or loosening. (Please refer to page 4.)
5. Attention in maintenance (At the alignment)
The beam flange of the safety cover for CE Marking is fixed with a small space 2 exists
between the beam cover pipe installed in output mirror holder. You should adjust the
optical axis of the resonator after loosening bolt 1 when you maintain laser. After the
alignment, you should adjust to keep a small space 2 between the hole of beam flange
and the beam cover pipe. And, please keep a small space 2, and fix the beam flange with
bolt 1. When you do not loosen bolt 1, you cannot adjust the beam mode correctly by
interfering with the beam flange and the beam cover pipe.
(Please refer to page 4.)

Contents Summary of Change the Structure of the Safety Cover of LASER C Series for CE Marking Additional Manual

  • Page 1Change the structure of the safety cover of LASER C series for CE Marking 1. Outline In outer of the shutter unit, the absorber unit, and LD unit of laser C1000-E, C2000-E and C4000-E for CE Marking, there are the safety cover for the shading of direct light and/or indirect light that it is visible
  • Page 2The present safety cover (Before changing) Safety cover Laser beam Front view of C4000-E Beam folding unit’s front view of C4000-E (View A) (View B) Safety cover B Beam folding unit Laser beam Output mirror holder Upper view of C4000-E A Title Change the structure of the safety cover of LASER C seri
  • Page 3The simple safety cover (After changing) Beam folding unit Laser beam Front view of C4000-E Beam folding unit’s front view of C4000-E (View A) (View B) Sutter unit B LD unit Simple safety cover Beam folding unit Laser beam Output mirror holder Upper view of C4000-E A Title Change the structure of th
  • Page 4Attention in maintenance (At the alignment) Sutter unit Bolt 1 Beam flange Simple safety Beam cover pipe cover Laser beam Output mirror holder Backside view of C4000-E Bolt 1 ● Please loosen 1 at the alignment. Space 2 between beam ● Please tighten 1 again so that the space flange and beam cover (2)