EDIT.
FANUC LTD
FANUC LTDFANUC LTD
FANUC LTD
SHEET
DRAW. NO.
CUST.
TITLE
DESCRIPTIONDESIG.DATE
B-63173EN/02-02
⑤ Setting connector number
No.
1936 Connector number of 1
st
interface unit
1937 Connector number of 2
nd
interface unit
Date type :Byte
Data range:0~3(in case of analog servo interface unit)
0~7(in case of separate type detector interface unit)
In case of using interface unit, set the value, which subtracts 1 from the
connector number of each axis. Therefore, the number of connector 1~8
corresponds to 0~7.
Set 0 to the axis without interface unit
It is possible to use any connectors at any axis, but use the connector from
the small number. So, do not use the connector number 4 without using 3.
3)Turning off/on the power to Power Mate i
The description of setting continues to 4) Servo initial setting.
FSSB Setting example in case of using analog servo interface unit
[Example1:in case of two analog servo axis]
The analog servo interface unit is slave 1. Analog servo amplifiers are considered
as they are connected after the analog servo interface unit. So they are slaves 2 and
3.
No. 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919
6 0 40 40 40 40 40 40 40
No. No.1023 No.1905 No.1936 No.1937
X
0000000 0 0
Y
0000000 0
Power mate i
Analog servo
amplifier 1
X axis
Analog servo
interface
unit
(Basic unit)
JV11L
JV12L
Slave 1
Slave 2
Slave 3
24
Analog servo
amplifier 2
Y axis