B-66284EN/01 2.DEVELOPMENT OF CUSTOM SCREEN
- 123 -
- NoAction Image
This tab is valid when [NoAction] on the [Action] tab is checked.
NoAction Signal:
Check this check box to use the embedded-plug-style indication
by an invalid signal. This function disables the function of the
screen switching control and displays the embedded plug style
when the invalid signal specified in the following boxes is
detected during power-up.
When this check box is checked, the following items can be set.
Image File Name:
This box can be used to select the FIG file that contains the
button styles used when the screen switching control is in the
invalid state.
Style:
Select the type of the button styles registered in the file specified
in [Image File Name].
State Color:
Select the color of the indicator lamp section.
Border Color 1:
Select the color of the upper and left ends of the button.
Border Color 2:
Select the color of the lower and right ends of the button.
PMC Area:
Specify the type of the PMC address of the invalid signal. The
following areas can be specified.
R, D, K, X, Y, G, F, E(PMC-SB7)
Address:
Specify the PMC address of the invalid signal.
Bit:
Specify the bit position (between 0 and 7) of the above signal
address.