OPERATION11. SETTING AND DISPLAYING DATA B–63664EN/02
672
Displays the following positions on a screen : Current positions of the
beam in the workpiece coordinate system, relative coordinate system, and
machine coordinate system, and the remaining distance. The relative
coordinates can also be set on this screen. See III–11.1.2 for the
procedure.
Procedure for displaying overall position display screen
1 Press function key
POS
.
2 Press soft key [ALL].
(RELATIVE)
X 246.912
Y 913.780
Z 1578.246
(ABSOLUTE)
X 123.456
Y 456.890
Z 789.123
(MACHINE)
X 0.000
Y 0.000
Z 0.000
(DISTANCE TO GO)
X 0.000
Y 0.000
Z 0.000
MEM **** *** *** 09:06:35
[ ABS ] [ REL ] [ ALL ] [ HNDL ] [ OPRT ]
ACTUAL POSITION O1000 N00010
PART COUNT 5
RUN TIME 0H15M CYCLE TIME 0H 0M38S
ACT.F 3000 MM/M S 0 T0000
D Display with one–path control
The current positions of the beam in the following coordinate systems are
displayed at the same time:
D Current position in the relative coordinate system
(relative coordinate)
D Current position in the work coordinate system
(absolute coordinate)
D Current position in the machine coordinate system
(machine coordinate)
D Distance to go (distance to go)
The distance remaining is displayed in the MEMORY or MDI mode. The
distance the beam is yet to be moved in the current block is displayed.
The least command increment is used as the unit for values displayed in
the machine coordinate system. However, the least input increment can
be used by setting bit 0 (MCN) of parameter No. 3104.
Only the coordinates for the first to fifth axes are displayed initially
whenever there are six or more controlled axes. Pressing the
[ALL] soft
key displays the coordinates for the sixth and subsequent axes.
Relative coordinates cannot be displayed together with absolute
coordinates whenever there are five or more controlled axes. Pressing the
[ALL] soft key toggles the display between absolute and relative
coordinates.
The total position display screen also supports the resetting of the relative
coordintes to 0 or presetting of them to specified values. See the procedure
for resetting the relative coordintes described in Subsection III–11.1.2
11.1.3
Overall Position
Display
Procedure
Explanations
D Coordinate display
D Distance to go
D Machine coordinate
system
D Displaing the sixth and
subsequent axes
D Displaying the fifth and
subsequent axes
D Resetting the relative
coordinates