3.TROUBLESHOOTING AND ACTION TROUBLESHOOTING B-65285EN/03
- 132 -
3.4.44 Alarm Code 84
The spindle sensor signal was disconnected.
Refer to Alarm Code 73 for this alarm trouble shooting.
3.4.45 Alarm Code 85
The one-rotation signal of the spindle sensor occurred in an incorrect
location.
Refer to Alarm Code 81 for this alarm trouble shooting.
3.4.46 Alarm Code 86
No spindle sensor one-rotation signal occurred.
Refer to Alarm Code 82 for this alarm trouble shooting.
3.4.47 Alarm Code 87
A spindle sensor signal is abnormal.
Refer to Alarm Code 83 for this alarm trouble shooting.
3.4.48 Alarm Code 88
The heat sink cooling fan is not running.
If this alarm is issued, replace the SPM heat sink cooling fan.
3.4.49 Alarm Codes A, A1, and A2
The control program is not running.
An error was detected when the control program was running.
(1) If this alarm is issued when the spindle amplifier power is
switched on
(a) Wrong software specification
(b) Defective printed-circuit board
Replace the SPM or SPM control printed-circuit board.
(2) If this alarm is issued when the motor is active.
(a) Influence by noise
Referring to "Installation" in "FANUC SERVO
AMPLIFIER αi series Descriptions (B-65282EN)," check
the grounding wire. If the spindle sensor signal wire is
bundled together with any motor power wire, separate them.