B-65285EN/03 START-UP PROCEDURE 5.PERIODIC MAINTENANCE OF SERVO AMPLIFIER
- 65 -
WARNING
1 When using the built-in batteries (A06B-6073-
K001), do not connect them to the BATL (B3) of
connector CXA2A/CXA2B.
The output voltages from different SVM batteries
may be short-circuited, resulting in the batteries
becoming very hot.
2 Do not connect more than one battery to the same
BATL (B3) line. If the output voltage is different
between the batteries, they may be short-circuited,
resulting in the batteries becoming very hot.
3 Install the battery with correct polarity. If the battery
is installed with incorrect polarity, it may overheat,
blow out, or catch fire.
[Installation procedure for the battery]
(1) Remove the battery cover from the SVM.
(2) Install the battery in the SVM as shown in the figure below.
(3) Install the battery cover.
(4) Attach the battery connector to CX5X of the SVM.
Battery
SVM
Battery cover
Inserting direction
Red: +6 V
Black: 0 V
CX5X
+6 V
0 V
Connector
Cable side
CAUTION
1 When the battery is installed in the SVM from the
side from which the cable is drawn, the cable may
be stretched tight, which can lead to a poor contact
condition. Therefore, install the battery so that the
cable is not extended tightly.
2 Be careful when handling the connector. See
[Caution No. 2 for battery replacement] at the end of
this section for details.