C. ERROR CODE APPENDIX B-75044EN/02
-220-
0x00060121 An error occurred during reading and writing of NC parameters.
Make sure that the correct NC name is set to <Machine Type> on the
[Machine Information] tab in the Machine Setup menu, and check <Bit Type
Data Type> on the [Communication Tab].
0x00060123 Cannot connect to the NC by Ethernet.
Check the “DNC1/Ethernet” setting in “2.6.3 Setups Relating to Machine
Communication” and the Ethernet cable connection.
0x00060125 An M198 call was received during DNC operation.
M198 calls are not accepted. Make sure that the program name is not
specified in “Select DNC File” in the NC's “Communication OP” screen.
0x00060126 An non-existent axis was specified during reading or writing of NC
parameters.
Check the maximum number of axes usable on the NC and the details of the
axis specification.
0x00060128 Cannot connect to the C4 server.
Check the “DNC1/Ethernet” setting in “2.6.3 Setups Relating to Machine
Communication” and the Ethernet cable connection.
0x0006012a The survival signal from the NC is interrupted.
Probable causes are that the NC was turned OFF, or that the Ethernet cable is
not connected. So, processing cannot be executed. Check the NC power
supply and Ethernet cable.
0x0006012c Download or upload started by the host was canceled by the cancel function.
0x0006012d Though canceling of download or upload started by the host was requested by
the host, the requested service is not currently being executed.
Check the machine number to be canceled and the cancel details.
0x0006012e The NC program that is requested for downloading and DNC program does
not contain an O number.
Check the contents of the NC program.
0x0006012f The parameter number specified during reading and writing of parameters
does not exist.
Check the parameter number.
0x000604f0 The NC was turned OFF during Ethernet communications. Or, the Ethernet
cable was cut.
Check the NC power supply and Ethernet cable.