B-75044EN/02 APPENDIX C. ERROR CODE
-227-
0x10040111 Cannot find the execution format file for the communication process.
0x10040114 A machining center tool offset type is specified together with a lathe tool
offset type during reading and writing of the tool offset.
0x10040118 (1) “0” (zero) was specified as the number of data items during reading and
writing.
Set within the range 1 to 32.
0x10040118 (2) The tool offset type was not specified during reading and writing of the tool
offset.
Specify the tool offset type.
0x10040119 No valid notification message
0x1004011c The CDA Manager is not functioning.
When CDA Manager cannot function properly, check that
FANUC_PCFA_CDA is set to the services file.
A line feed is needed at the end of each line of data registered to the services
file.
0x1004011d No machines are set in the Machine Setup screen.
0x1004020f The Communication Manager is not functioning.
A probable cause is that F_Open was executed without executing
F_CreateCommunication, or that F_Close was executed after
F_TerminateCommunication was executed.
0x10040210 FANUC_PCFA_APP is not specified in the service file.
0x10060001 An attempt was made to open an already opened List File.
Close the file and try opening it again.
0x10060002 Failed to open the List File.
When an attempt is being made to manipulate the List File by machine, make
sure that the transfer is being carried out, and that the machine number is
correct.
When an attempt is being made to manipulate an existing original List File,
make sure that another process is not manipulating the same file, and that the
specified file name is correct.
When an attempt is being made to manipulate a new original List File, make
sure that the specified file is correct.
0x10060003 The specified List File does not exist.
Make sure that the specified List File does not contain any errors.