8.LASER OPTICAL SYSTEM B-70315EN/02
- 242 -
(c) Obtain a maximum power based on FM1 by using the R.M.
as the reference.
(d) Collect a burn pattern. If the mode is good, end this
procedure. If not, start all over again from step (a). At this
time, collect a burn pattern in each step. If the mode is
finally good, end this procedure.
(3) For C4000-E
(a) Obtain a maximum power based on O.C. by using the R.M.
as the reference.
(b) Obtain a maximum power based on FM4 by using the R.M.
as the reference.
(c) Obtain a maximum power based on FM4 by using the O.C.
as the reference.
(d) Obtain a maximum power based on FM2 by using the O.C.
as the reference.
(e) Obtain a maximum power based on FM6 by using the R.M.
as the reference.
(f) Collect a burn pattern. If the mode is good, end this
procedure. If not, start all over again from step (a). At this
time, collect a burn pattern in each step. If the mode is
finally good, end this procedure.
(4) For C5000-E
(a) Obtain a maximum power based on O.C. by using the R.M.
as the reference.
(b) Obtain a maximum power based on FM4 by using the R.M.
as the reference.
(c) Obtain a maximum power based on FM4 by using the O.C.
as the reference.
(d) Obtain a maximum power based on FM2 by using the O.C.
as the reference.
(e) Obtain a maximum power based on FM6 by using the R.M.
as the reference.